Skip to content
SoilX

Cone penetration test quality assurance: Show that the measurement chain is sound.

ConeCheck lets you check the CPT cone and measurement chain in the field – before use, after unusual contact or between two tests. Zero readings, drift and calibration reference are compared, and the result goes to the cloud as a status and a history entry, while Cone Management keeps a digital life record for every cone. ConeCheck supplements quality assurance but does not replace any required calibration. Both modules are in development.

Why the cone needs checking

A cone penetration test is only as good as the load cells in the cone. Cone resistance and sleeve friction are measured with strain gauges, and their zero reading can shift – through temperature changes, overloading against an obstruction, dirt or wear. Whether the cone, cable and measurement chain are working properly often only becomes clear from odd readings, and at worst after the test. Queries, repeat tests and extra site visits follow.

EN ISO 22476-1 therefore requires cones to be calibrated at set intervals and the zero readings to be recorded before and after every test. The standard also assigns tests to application classes with different accuracy requirements. Showing that a test meets those requirements takes more than saying "the cone is fine".

ConeCheck: a documented field check

ConeCheck is designed for the period between two calibrations. The check runs at the rig: before use, after unusual contact such as a cobble or obstruction, or between two tests. It compares the zero readings of the load cells, their drift and the reference to the last calibration.

The result does not stay in the field book; it goes to the cloud as a status and as an entry in the cone's history. The office can see which cone is in use and in what condition before the first test is evaluated. When the test is streamed live, an engineer watching the readings spots anomalies immediately rather than during the evaluation.

Real-time cone penetration test data: how readings reach the office

Cone Management: a life record for every cone

Calibration certificates, deployment lists and inspection records are often kept in different folders. Cone Management brings them together for each CPT cone: deployments, ConeCheck results, calibration data, certificates and warnings such as "calibration due".

When a test is prepared, the probe, cone and calibration information are assigned to it. Every test therefore knows which cone produced it, and every cone knows which tests it took part in. If a cone fails a check, you can trace which earlier tests were carried out with it.

Evidence in the report, not a promise on the phone

The checks are meant to add up to documented quality assurance. The Reports and QA module is designed to bring together measurement reports, ConeCheck records, calibration information and inspection notes without hunting for individual files. A geotechnical consultancy or client can then see the conditions under which a test was carried out.

The aim is fewer repeat tests, fewer queries and results that can be traced back to the measurement and the cone used. How much difference that makes in your business depends on your workflows and can be assessed together in a pilot.

SoilX for geotechnical consultants

Limits and status

ConeCheck is a documented field check between calibration intervals. It supplements quality assurance but does not replace any required calibration, certification or manufacturer inspection. Calibrating the load cells remains the job of the manufacturer or a calibration laboratory; SoilX brings the results together and makes them visible day to day.

  • ConeCheck – field check of cone and measurement chainIn development
  • Cone Management – life record for every CPT coneIn development
  • Reports / QAIn development
  • Live CPT – live view of the cone penetration testField trial

Questions about checking CPT cones

Does ConeCheck replace calibration of the CPT cone?

No. ConeCheck is a documented field check between calibration intervals – before use, after unusual contact or between tests. It supplements quality assurance but does not replace any required calibration, certification or manufacturer inspection.

What is zero drift in a cone penetration test?

Zero drift is a shift in the zero readings of the load cells, that is, their output with no load applied. It shows up when the zero readings before and after a test are compared, and can be caused by temperature, overloading, dirt or wear. EN ISO 22476-1 requires the zero readings to be recorded.

When should a CPT cone be checked in the field?

ConeCheck is designed for three moments: before use, after unusual contact with an obstruction, and between two tests. The result goes to the cloud as a status and a history entry.

What belongs in the life record of a CPT cone?

Cone Management brings together deployments, ConeCheck results, calibration data and certificates for each cone, and warns you, for example, when calibration is due. Every test is linked to the cone that was used.

How can I show a client that the measurement chain was sound?

Check results and calibration information are stored in the cone's history and linked to the test. The Reports/QA module, which is in development, is intended to bring measurement reports, ConeCheck records, calibration information and inspection notes together for the report.

Are ConeCheck and Cone Management available yet?

Both modules are in development. We will discuss with you which checks and data make sense for your cones, and we offer a pilot as a starting point.

Discuss your project.

Tell us briefly which measurement data you collect and what currently holds up the evaluation. You will receive a professional assessment in return — not a sales quote.

Contact persons

Stephan Heuer
Denis Schimanski