This glossary explains the key terms of cone penetration testing and ground investigation, each in a short section: what is measured, how the values relate and how to read them. Every entry opens with a one-sentence definition and points to the relevant page about SoilX, the cone penetration testing software from Kiel, Germany.

Cone penetration test (CPT)

The cone penetration test (CPT) is a ground investigation method in which a cone-tipped probe is pushed into the ground at a constant rate while resistances are measured continuously.

The electrical cone penetration test is standardised in EN ISO 22476-1. The standard cone has a 60° apex angle and a base area of 10 cm², with a friction sleeve behind it; the rate of penetration is 20 mm/s with a permitted deviation of 5 mm/s. Cone resistance and sleeve friction are measured, and with a piezocone also the pore water pressure. Because readings are recorded centimetre by centimetre, the test picks up thin layers that a borehole can easily miss. It does not recover soil samples, however, so it is usually combined with boreholes.

Real-time cone penetration test data: how readings reach the office

Piezocone (CPTu) and pore water pressure

The piezocone test (CPTu) is a cone penetration test in which the probe also measures pore water pressure, the pressure of the water in the soil's pores.

It is measured through a saturated filter, usually directly behind the cone; this reading is called u2. Pore pressure shows how the soil responds to penetration: in sand it usually stays close to the groundwater pressure because water can drain quickly, while in soft clay it rises markedly. With u2, the corrected cone resistance qt can be calculated, which compensates for the effect of pore pressure on the cone reading. If the test is paused and the decay of pore pressure is observed, this is called a dissipation test – it gives an indication of the soil's permeability and consolidation behaviour.

Real-time cone penetration test data: how readings reach the office

Cone resistance qc

Cone resistance qc is the resistance the soil offers to the cone, expressed as the force on the cone divided by its base area, usually in MPa.

qc is the most important reading in a cone penetration test. Coarse-grained, dense soils such as sand and gravel produce high cone resistance; soft fine-grained soils and peat produce low values. The profile over depth therefore shows at a glance where competent layers begin and where soft layers lie. Density, strength and bearing capacity are among the properties estimated from cone resistance. In a piezocone test, qc is converted using the pore pressure u2 into the corrected cone resistance qt, which is more accurate in fine-grained soils in particular.

Real-time cone penetration test data: how readings reach the office

Sleeve friction fs

Sleeve friction fs is the friction between the soil and the friction sleeve behind the cone, expressed as the friction force divided by the sleeve area.

In fine-grained soils, sleeve friction is high relative to cone resistance; in sand and gravel it tends to be low. On its own, fs therefore says less than in relation to qc – see friction ratio. The measurement is more sensitive than cone resistance: wear and roughness of the sleeve, dirt and zero drift have a greater effect. That is why it pays to check the friction sleeve and the measurement chain regularly and to document those checks.

Checking the CPT cone: ConeCheck and Cone Management

Friction ratio Rf

The friction ratio Rf is sleeve friction divided by cone resistance, expressed as a percentage: Rf = fs / qc × 100 %.

The friction ratio is a first indication of the soil the cone is passing through. Coarse-grained soils such as sand have a low friction ratio, fine-grained soils such as silt and clay a higher one, and organic soils such as peat often a very high one. In a piezocone test, the corrected cone resistance qt is usually used instead of qc. Together with cone resistance, the friction ratio forms the basis of the Robertson classification. It is an indication, not a soil description: silty sands or cemented layers can give values similar to other soils.

Real-time cone penetration test data: how readings reach the office

Soil behaviour type (SBT) after Robertson

The soil behaviour type (SBT) after Robertson assigns each data point of a cone penetration test to a zone of similar soil behaviour, based on cone resistance and friction ratio.

Peter K. Robertson published classification charts for this purpose that distinguish zones from sand-like through silt-like to clay-like and organic – in normalised form also taking account of the stresses in the ground. The name matters: the method describes how the soil behaves mechanically during penetration, not its grain size distribution. A stiff, overconsolidated clay can behave differently from a soft clay of the same composition and fall into a different zone. The soil behaviour type is therefore a tool for a quick assessment and for comparing tests; it does not replace logging of borehole samples or professional judgement.

Real-time cone penetration test data: how readings reach the office

SoilX for geotechnical consultants

Ground level (GL)

Ground level (GL) is the surface of the ground at the location of a borehole or cone penetration test and the reference point for all depths.

Depths are given in metres below ground level, written "m bgl". So that tests and boreholes at different locations can be compared, the elevation of the ground level itself is surveyed as well, in Germany usually in metres above the national height datum (NHN). Only with that elevation can layer boundaries and groundwater levels from several investigation points be placed correctly side by side in a cross-section. If the ground level is wrong, every layer in that record shifts by the same amount.

Digital borehole logs from the rig

Borehole magnetometer survey

A borehole magnetometer survey is a UXO investigation method in which a magnetometer is lowered into a pre-drilled borehole to locate ferrous objects in the surrounding ground.

Surface surveys only reach a few metres deep. Where greater depths have to be checked for unexploded ordnance before drilling, piling or foundation work, measurements are therefore taken in the borehole, usually inside a plastic casing so that the casing does not disturb the magnetic field. The magnetometer records disturbances of the Earth's magnetic field around the borehole and assigns them to a depth. A related method is the magnetometer CPT, in which the magnetometer is pushed into the ground by a CPT rig. In both cases an anomaly is first of all a signal; whether it is UXO is decided by the UXO specialist or qualified person. SoilX MagnetoMonitor is currently designed for magnetometer CPT with a CPT rig.

Magnetometer CPT for UXO surveys

Borehole log

The borehole log is the record of a borehole, noting the depth and soil description of every stratum encountered.

For each stratum it records the depth to its base, the description by principal and secondary fractions according to EN ISO 14688-1, colour, consistency or density, and inclusions. It also covers groundwater observations, samples taken and header data such as location, ground level elevation, drilling method and date. For drawings and reports, the log is presented graphically as a borehole profile. Because it is written at the rig, its quality depends heavily on how completely and consistently the details are captured there.

Digital borehole logs from the rig

Quick questions

What is the difference between CPT and CPTu?

In a CPT, the probe measures cone resistance and sleeve friction. In a CPTu, or piezocone test, it also measures pore water pressure, usually as u2 directly behind the cone. This allows the corrected cone resistance qt to be calculated and makes the behaviour of fine-grained soils easier to recognise.

How is the friction ratio Rf calculated?

The friction ratio is sleeve friction divided by cone resistance, expressed as a percentage: Rf = fs / qc × 100 %. In a piezocone test, the corrected cone resistance qt is usually used instead of qc.

What does m bgl mean?

It stands for metres below ground level. All depths in a borehole or cone penetration test refer to the ground surface at the test location, whose elevation is surveyed separately – in Germany usually in metres above the NHN height datum.

Is the Robertson soil behaviour type the same as the soil type?

No. The soil behaviour type describes how the soil responds mechanically to penetration, while the soil type describes its composition by grain size. The two are related but can differ; the soil type is determined from borehole samples.

Discuss your project.

Tell us briefly which measurement data you collect and what currently holds up the evaluation. You will receive a professional assessment in return — not a sales quote.

Contact persons